Key result
Balloon-expandable TAVR linked to ~54% lower 30-day major cardiovascular events vs. self-expanding valves in aortic regurgitation.
Why the study?
TAVR remains off-label for pure native aortic regurgitation because lacking annular calcification and aortic root dilation hinder anchoring, while dedicated systems have limited availability.
Does transcatheter aortic valve replacement using balloon-expandable valves compared to self-expanding valves improve technical success and reduce major adverse cardiac events in high-risk patients with severe native aortic valve regurgitation?
Cohort (n=104)
Yes
Does transcatheter aortic valve replacement using balloon-expandable valves compared to self-expanding valves improve technical success and reduce major adverse cardiac events in high-risk patients with severe native aortic valve regurgitation?
In high-risk patients with severe native aortic valve regurgitation, off-label TAVR with contemporary commercial valves achieves acceptable technical success (79.8%) with lower 30-day MACE using balloon-expandable valves, though long-term outcomes are driven by baseline patient and anatomic comorbidities rather than valve type.
Answers are grounded in this paper and cite their sources.
May favor balloon-expandable valves for off-label TAVR in native AR; leaves open randomized confirmation before practice change.
Transcatheter aortic valve replacement (TAVR) is the standard of care for severe aortic stenosis but remains off-label for pure native aortic regurgitation (NAVR), where the absence of annular calcification and frequent aortic root dilation hinder anchoring and predispose to valve migration and paravalvular leak.1 Dedicated NAVR systems such as JenaValve and J-Valve have shown promise, yet their availability is limited, and the off-label use of commercial transcatheter heart valves (THVs) remains common.
No takes yet. Share an insight, caveat, or question.
Kumar et al. (2025) conducted a cohort in Severe native aortic valve regurgitation (NAVR) (n=104). Balloon-expandable transcatheter heart valves (BEVs) for TAVR vs. Self-expanding transcatheter heart valves (SEVs) for TAVR was evaluated on 30-day major adverse cardiac events (MACE: composite of death, myocardial infarction, stroke, or cardiac rehospitalization) (adjusted OR 0.46, 95% CI 0.10-0.96, p=0.040). Balloon-expandable TAVR was associated with lower 30-day major cardiovascular events compared to self-expanding TAVR in severe native aortic regurgitation.
Synapse has enriched 10 related papers. Consider them for comparative context: