Answers are grounded in this paper and cite their sources.
Background Retreatment after Woven EndoBridge (WEB) embolization is required in a subset of patients, yet the role of repeat WEB implantation remains poorly defined. Objective To evaluate the feasibility, safety, and angiographic characteristics of repeat WEB implantation for recurrent intracranial aneurysms. Methods We retrospectively reviewed a contemporary single-center cohort of 209 consecutive intracranial aneurysms treated with the WEB device between January 2020 and December 2024. Retreatment was defined as any additional endovascular or surgical procedure performed for aneurysm recurrence or incomplete occlusion during follow-up. Patients undergoing repeat WEB implantation were analyzed as a focused subgroup within this consecutive single-center cohort. Results Retreatment was required in 21 of 209 aneurysms (10.0%). Retreatment strategies included flow diversion (n = 14), coiling (n = 1), and repeat WEB implantation (n = 6; 2.9% of the total cohort). Recurrence mechanisms prompting repeat WEB included device compaction (n = 5) and combined growth and compaction (n = 1). Repeat WEB implantation was technically successful in all cases, with no procedure-related hemorrhagic or ischemic complications. One patient subsequently required flow diversion due to parent artery stenosis. Conclusion Repeat WEB implantation appears feasible and safe in carefully selected patients and may serve as a complementary or bridging retreatment strategy after initial WEB embolization.
No takes yet. Share an insight, caveat, or question.
Akimoto et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: