Mock-ups preview esthetic and functional outcomes and may guide minimally invasive tooth preparation. This in vitro study compared conventionally, additively, and subtractively fabricated six-unit anterior mock-ups with patient-specific digital designs. Ten patient-specific designs were each used to fabricate one six-unit mock-up by conventional impression (CM), additive manufacturing (AM), and subtractive manufacturing (SM), yielding 30 specimens. Surface matching was defined as the percentage of the evaluated labial surface within ± 0.10 mm of the reference following local best-fit registration using the same labial surfaces. Absolute digital and caliper-based linear deviations and signed labial depth deviations by tooth type, inciso-cervical level, and mesio-distal position were assessed. Patients served as matched experimental units. Exact Friedman tests and paired exact Wilcoxon signed-rank tests with Holm adjustment were used; regional analyses were exploratory. Under the applied labial best-fit registration, surface matching was 74.54 ± 12.26% for SM, 58.72 ± 18.84% for AM, and 42.80 ± 12.46% for CM (exact P = 0.002). SM exceeded CM (Holm-adjusted P = 0.006); other pairwise differences were not significant. Absolute digital and caliper-based linear deviations did not differ significantly among workflows. Patient-level signed depth deviations were 0.022 ± 0.022 mm for SM, 0.015 ± 0.029 mm for AM, and − 0.002 ± 0.033 mm for CM (exact P = 0.030); SM differed from CM (Holm-adjusted P = 0.012). When averaged across manufacturing workflows, mean signed depth deviations differed by tooth type; however, workflow-specific patterns were not uniform, with consistently positive canine deviations and variations in central- and lateral-incisor deviations among workflows. Mesio-distal positions did not differ significantly. Under the present labial best-fit registration conditions, SM showed a higher observed surface-matching percentage than CM, while AM was numerically intermediate without significant differences from either workflow. This finding reflects agreement under the applied registration conditions and does not provide independent evidence of superior trueness for SM. No statistically significant differences in absolute linear deviations were detected among workflows. Although overall signed depth deviations were small, SM and CM differed. Mean signed depth deviations differed by tooth type when averaged across manufacturing workflows; however, workflow-specific patterns were not uniform.
No takes yet. Share an insight, caveat, or question.
Alver et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: