Answers are grounded in this paper and cite their sources.
Complete standalone manuscript, vector figures, prospectively pre-registered specification, compiled Qiskit QPY binary (SHA-256 357a29ad2746e2be94522702516dce3e04319894c1dc981596c9a3640041c056), pre-submission calibration snapshot, Edmonds Blossom MWPM decoder, and verbatim 192-circuit raw bitstring archive (physical_qec001_fez_raw_counts.json.gz, SHA-256 cdae697c364e2aad2085cc3585039d079baf4b3d1bb619dcb6178647b75646c1) for benchmark OSIRIS-QEC-001 executed on the 156-qubit IBM Heron r2 superconducting processor ibm_fez (IBM Runtime Job dbtl2vb2kf8s73c9a0d0, 192 dynamic mid-circuit measure+reset circuits × 2,048 shots = 393,216 shots, resilience_level=0, zero postselection, pre-submission calibration decoder priors). Monotonic Sub-Threshold Suppression Across All 8 (basis, R) Curves: Across concentric subchains d ∈ {3, 5, 7} (5, 9, and 13 transmons on [111,110,109,108,107,106,105,117,125,124,123,122,121]) and syndrome cycles R ∈ {1, 3, 5, 7} (16,384 pooled shots/cell), logical error per cycle satisfies ε_L(3) > ε_L(5) > ε_L(7) everywhere. At R = 7, bit_flip_z drops from 0.00731 ± 0.00026 (d=3) to 0.00211 ± 0.00025 (d=5) and 0.00195 ± 0.00018 (d=7; Λ3→7 = 3.75×, QEC-H1 PASS). Real-Time Error Correction of a Live q107 T2 = 18.17 μs Hotspot: Pre-submission calibration captured a localized coherence hotspot on data transmon q107 inside the d=3 core (T2 = 18.17 μs, giving p_Z = 8.38% thermal phase-flip probability per 3.344 μs mid-circuit measure+reset window, vs T2 ∈ [45.2, 176.8] μs on surrounding d=5, 7 data qubits). Expanding d = 3 → 5 → 7 actively corrected q107 across all 7 cycles, suppressing phase_flip_x logical error per cycle from 0.02301 ± 0.00051 (d=3) to 0.00592 ± 0.00025 (d=5, 3.89×) and 0.00265 ± 0.00020 (d=7, Λ5→7 = 2.23×, Λ3→7 = 8.69×; QEC-H2 PASS). Space-Time Blossom MWPM Gain & Un-Doctored QEC-H3 Ceiling: At R = 7, space-time MWPM reduced logical errors over final-round majority vote by 7.22× (bit_flip_z d=7: 221 vs 1,596 errors) and 4.86× (phase_flip_x d=7: 299 vs 1,453 errors), while phase_flip_x R = 7 detector defect density reached 0.1265–0.1284 vs the pre-registered 0.1200 second conjunct of QEC-H3 (preserved verbatim). Scope Note: 1D repetition codes protect one Pauli sector (Z or X) per circuit run within standard open-system quantum mechanics, rather than simultaneous 2D logical qubits.
No takes yet. Share an insight, caveat, or question.
Devin Phillip Davis (2026) studied this question.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: