Answers are grounded in this paper and cite their sources.
Porous SiOC/silica aerogel composites were successfully fabricated through a combined route of precursor conversion, sol–gel reaction-induced phase separation, and impregnation. By varying the pyrolysis temperature, the pore structure of the SiOC matrix was tailored, which directly governed its mechanical strength. The optimal pre-impregnation properties, a compressive strength of 163.65 ± 11.39 MPa and a modulus of 5.87 ± 0.12 GPa, were achieved at 1200 °C. Subsequent silica aerogel impregnation further enhanced the compressive strength by approximately 7.9% while reducing the thermal conductivity from 0.274 to 0.261 W·m −1 ·K −1 . This work demonstrates that the synthesized composite is a promising candidate for thermal insulation applications requiring high mechanical load-bearing capacity.
No takes yet. Share an insight, caveat, or question.
Yan et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: