Answers are grounded in this paper and cite their sources.
Viscoelastic damping materials exhibit coupled dependencies on excitation frequency, deformation amplitude, and temperature. This study investigates Sylodamp® SP 1000 using a two-stage identification procedure based on a nonlinear fractional Kelvin model. First, four rheological parameters are identified at 20 °C from 30 harmonic shear tests covering frequencies of 1, 5, and 10 Hz and displacement amplitudes of 0.1–1.0 mm. Complex-domain harmonic balance yields a fractional order of α = 0.32025 and a root-mean-square relative first-harmonic force-amplitude error of 4.07% for the calibration data. Second, temperature-dependent measurements from −20 to +60 °C at a representative displacement amplitude of approximately 0.3 mm are used to determine horizontal shift factors described by the Williams–Landel–Ferry relation. The resulting model is evaluated against 135 temperature–frequency combinations using engineering error limits of 10% for the storage modulus and 20% for the loss modulus. Both criteria are satisfied in 23 cases (17.0%), exclusively at 10 and 20 °C. Selected hysteresis loops illustrate model performance but do not constitute independent validation. The results demonstrate that successful reference-temperature calibration and TTSP/WLF shifting do not necessarily ensure accurate temperature-dependent predictions, highlighting the importance of quantitatively assessing the applicability and inherent limitations of the adopted constitutive model.
No takes yet. Share an insight, caveat, or question.
Pawlak et al. (2026) studied this question.