Answers are grounded in this paper and cite their sources.
Maximum stress experienced by an electrode during cycling is shown to cause mechanical degradation and capacity fade, but the effect of potential window and stress range (Δσ) on cycling behavior was not investigated. Here, stresses generated in hard carbon (HC)-based porous composite electrodes were measured in situ while cycling under three different potential windows: (i) full window (2-0.0005 V vs Na/Na+), (ii) sloping (2-0.1 V vs Na/Na+), and plateau (0.1-0.0005 V vs Na/Na+) regions and three different C-rates. The stress range (Δσ), capacity, and mechanical hysteresis during sloping region were nearly rate-independent, while they showed significant rate dependence in the plateau region, suggesting two different ion-storage mechanisms. Both the stress range and mechanical hysteresis (indicator of irreversible deformation) increased at lower current densities during the plateau region, indicating higher irreversible mechanical work and degradation. During extended cycling, capacity continued to decrease even after the maximum stress saturated, indicating that Δσ and hysteresis are important to explain electrode degradation. Based on these observations, an optimized cycling protocol was used which reduced stress range and mechanical hysteresis while increasing specific capacity at faster rate, demonstrating the importance of coupled electro-chemomechanical responses for optimizing cycling protocols to improve capacity utilization and mechanical durability.
No takes yet. Share an insight, caveat, or question.
Chanda et al. (2026) studied this question.