DC-DC converters that interface photovoltaic (PV) generators with loads, batteries or inverters are highly stressed, and their faults directly reduce energy yield. This review examines fault diagnosis and fault-tolerant control (FTC) of PV DC-DC converters, with emphasis on observer-based and sliding mode techniques. Literature published between 2015 and 2026 was identified on five scholarly platforms and by citation tracking; 40 primary studies were classified and compared against 13 features, including fault coverage, detection speed, fault estimation, robustness to maximum power point tracking (MPPT) and irradiance transients, sensor needs, computational load and validation level. Two-thirds were published since 2021. Switch faults dominate (25 studies), whereas sensor (11) and component faults (6) receive less attention; 14 studies implement an FTC action, and 11 report experimental validation. Sliding mode observers form the largest and fastest-growing family (14 studies, 13 since 2021) and combine robustness with fault reconstruction, but experimental results are reported for only one of them, on a PV inverter. A framework linking fault classes, diagnosis information, FTC strategies and reaction times is proposed, with a design procedure and a combined-uncertainty validation protocol. Closing the loop between model-based diagnosis and FTC under realistic PV conditions remains the main open need.