Answers are grounded in this paper and cite their sources.
Aluminum alloys used as electrical conductors in power transmission and cable systems require a combination of medium-to-high strength, adequate ductility and high electrical conductivity. In this work, an Al-Fe-Cu-Mg alloy was designed and processed by hot rolling to thickness reductions of 50–90%, followed by annealing at 240–260 °C for 3 h with cooling rates of ~2 °C/s for air cooling and ~0.1 °C/min for furnace cooling, respectively. The as-rolled sheets consist of elongated deformed grains with a β-fiber rolling texture; subsequent annealing proceeds predominantly by recovery, and recrystallization is strongly suppressed by the Zener pinning of fine particles. Coarse Al13(Fe,Cu)4 and Al7Cu2Fe constituent particles are fragmented and aligned along the rolling direction, whereas fine, near-spherical Al2CuMg particles with an equivalent circle diameter of 84.6 ± 37.8 nm provide an Orowan strengthening of approximately 52.7 MPa. The softening upon annealing is dominated by dislocation annihilation, as confirmed by XRD dislocation-density measurements. The electrical conductivity increases from 54.19% IACS in the 90%-reduced sheet to 57.05–57.57% IACS after annealing. Annealing at 240 °C with furnace cooling gives the best strength–ductility–conductivity balance, with an ultimate tensile strength of 172.8 MPa, an elongation of 13.8% and a conductivity of 57.57% IACS, which meets the combined property requirements of electrical conductor-strip applications.
No takes yet. Share an insight, caveat, or question.
Zeng et al. (2026) studied this question.