Answers are grounded in this paper and cite their sources.
Solar-driven combined cooling, heating, and power (CCHP) systems require coordination of useful outputs, energy quality, and economic cost. This study examines these trade-offs in a parabolic trough collector (PTC)-driven system integrating a dual-turbine cascaded transcritical CO2 power cycle with an embedded ejector refrigeration cycle. Liquid-phase pumping, split-flow heating and expansion, and two-stage recuperation couple power generation with residual heat recovery and pressure-potential recovery for cooling. Steady-state thermodynamic and exergoeconomic models support parametric analysis and multi-objective optimization, with thermodynamic calculations checked against published data. At a baseline direct normal irradiance (DNI) of 800 W/m2, the system supplies 7962 kW of net power, 19,989 kW of heating, and 3610 kW of cooling. Thermal and exergy efficiencies are 72.14% and 16.97%, respectively, with a total product unit cost of 7.59 $/GJ. The PTC accounts for 83.76% of total exergy destruction. The selected Pareto compromise achieves 93.04% thermal efficiency, 17.34% exergy efficiency, and a product unit cost of 7.75 $/GJ. These results identify the main bottlenecks and quantify trade-offs among outputs, efficiencies, and cost to support the selection of operating parameters under the modeled steady-state conditions.
No takes yet. Share an insight, caveat, or question.
Liu et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: