Answers are grounded in this paper and cite their sources.
Hyper-Kamiokande scales the proven water Cherenkov technique to a fiducial mass more than eight times that of its predecessor, on a site where the diffuse search can run with gadolinium tagging from early in operations. Scaling the computed signal and the tagged background by fiducial mass and propagating counting statistics gives the running time needed for three and five standard deviation evidence under the baseline flux. Headline values are h12 years to 3sigma flux low edge h12ledger = 8.756; h12 events in first year total h12ledger = 34.83; h12 fiducial mass ktonne h12ledger = 187; h12 mass ratio to superk h12ledger = 8.311; h12 signal per year tagged h12ledger = 8.646; h12 background per year tagged h12ledger = 26.18. Under the baseline flux and tagged backgrounds, Hyper-Kamiokande reaches three standard deviations in about three years of running and five in about nine; at the planning band's lower edge the three-standard-deviation point stretches to about nine years.
No takes yet. Share an insight, caveat, or question.
William Alexander Aldred (2026) studied this question.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: