Answers are grounded in this paper and cite their sources.
OBJECTIVES: To quantitatively assess in vivo ankle tendons using less magic angle-sensitive 3-dimensional ultrashort echo time magnetization transfer (UTE MT) imaging and to compare its intersubject variability with UTE T2* mapping in healthy volunteers. MATERIALS AND METHODS: Thirty healthy volunteer ankles were examined on a 3T MRI system using a standardized clinical protocol with additional 3D UTE MT and 3D multi-echo UTE T2* sequences (acquisition times: 4:16 and 9:52 minutes, respectively). Nine major ankle tendons were semi-automatically segmented to extract quantitative UTE MTR and UTE T2* values for each tendon. Variability for each sequence was assessed using the coefficient of variation (CV), and differences in CV were evaluated primarily with a paired bootstrap of the CV ratio and secondarily with a modified signed log-likelihood ratio (MSLR) test, both with Holm correction. Within-tendon angular dependence was assessed using local tendon fiber angles relative to B0. RESULTS: Absolute quantitative values differed between tendons, with the Achilles tendon demonstrating the lowest T2* values (2.15±0.43 ms) and highest MTR values (0.44±0.08), whereas smaller positional tendons showed higher T2* and lower MTR values. UTE MTR demonstrated lower overall variability compared with UTE T2* values across the 9 assessed tendons (overall CV UTE MTR: 18.0%±4.2% vs. UTE T2*: 33.7%±8.9%, mean±SD, n=9). In the paired bootstrap analysis with Holm correction, UTE MTR showed significantly lower variability than UTE T2* in 6 of 9 tendons, with the largest differences in the extensor digitorum longus, peroneus brevis, and flexor hallucis longus tendons (T2*/MTR CV ratio, 2.74, 2.60, and 2.48; all Holm-adjusted P≤0.015); MSLR results were consistent. Between 0 degree and the magic angle, UTE T2* increased by 79% (95% CI: 64%-95%), whereas UTE MTR decreased by 9% (95% CI: 7%-11%). UTE MTR consistently demonstrated reduced dispersion and narrower value distributions compared with UTE T2*. CONCLUSIONS: In vivo ankle tendon quantification using UTE MT is feasible within clinically acceptable acquisition times and shows significantly lower intersubject variability than UTE T2* mapping in most tendons, with reduced susceptibility to the magic angle effect. UTE MT represents a promising approach for quantitative assessment of tendon structure in vivo.
No takes yet. Share an insight, caveat, or question.
Feuerriegel et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: