Multi-effect distillation with thermal vapor compression (MED-TVC) is widely used for seawater desalination, but the mixing process in the steam ejector is associated with exergy destruction. This study investigates a six-effect MED system integrating turbine-driven mechanical vapor compression (MED-TDC), together with four selected feedwater preheating configurations. A steady-state model is developed to compare the energy, exergy, and exergoeconomic performance of the proposed systems with conventional MED-TVC. At a first-effect evaporation temperature of 60 °C, the baseline MED-TDC achieves a net gained output ratio (GOR) of 10.41, compared with 7.61 for MED-TVC, an increase of 36.9%. Among the four selected preheating configurations, TDC3 gives the highest net GOR of 10.87. Under the adopted nominal cost assumptions, MED-TVC has the lowest specific freshwater production cost of 1.175 $/m3, while TDC3 has the lowest value among the MED-TDC cases, at 1.194 $/m3. Within the explicitly resolved component boundary, the exergy-destruction sum is 398.26 MW for MED-TVC and 235.25–241.92 MW for the MED-TDC cases; the baseline MED-TDC has the lowest sum among the MED-TDC cases, whereas TDC3 has the highest. The results indicate that turbine-driven vapor compression increases net GOR under the reference conditions, while the selected feedwater arrangements produce configuration-dependent changes in component-level exergy destruction and nominal freshwater production cost.