Answers are grounded in this paper and cite their sources.
A hollow ZrO 2 ceramic array Load Bearing multi-layer insulation (LBMLI) is proposed for the radioactive thermophotovoltaic system (RTPV). Two theoretical models including the finite element model and layer-by-layer model are compared to analyze the thermal insulation performance. The number of layers, spacing, ceramic array quantity, thermal conductivity of spacing material, and reflective screen emissivity on heat loss are analyzed. At the LBMLI of 9 dots’ ceramic array, as the quantity of layers increased from 15 to 20, the heat power loss significantly decreased from 22.5 W to 17 W. By reducing the emissivity from 0.1 to 0.025, the heat loss is almost linearly reduce to 8.5 W. For mechanical stability, a 15-layer-screen ceramic array LBMLI is designed for the present RTPV, with 25 ceramic arrays in each layer. When the input power is 250 W, if not considering insulation frame heat loss of the ceramic array LBMLI, the temperature at heat source center could reach 1106.3 ℃, and the thermal efficiency of ceramic array LBMLI is 69.5%. When it is considered, the temperature of the heat source is 1079.4 ℃, and ŋ thermal is 57.0%. Moreover, considering optical cavity size, when reducing the lateral two dimensions of ceramic array LBMLI by 8 cm each, the temperature at heat source center changes to 1159.9 ℃ when considering insulation frame heat loss, with ŋ thermal being 60.2%. Results show that hollow ZrO 2 ceramic array LBMLI is expected to reduce the heat leakage.
No takes yet. Share an insight, caveat, or question.
Shao et al. (2026) studied this question.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: