Photovoltaic (PV) charging stations for light electric vehicles are commonly sized with typical-year irradiance and verified over short simulation windows, which conceals the seasonal variability that sizes storage and grid support. This study presents a dual-timescale assessment of a grid-connected charging station with a 4 kWp PV array, a 21.6 kWh lithium iron phosphate battery and four 0.8 kW charging ports. Daily energy-meter records of an operating 325 kWp car-park canopy PV plant in northern India (January--September 2026, 270 recorded days) were screened with seven IEC 61724-1-informed and statistical rules, with co-located campus meters as a reference to separate meter faults from weather. Suspect days were excluded, not altered; 257 days were retained (95.2 % coverage), and the mean specific yield changed by only 0.8 %. The retained days were capacity-scaled to 4 kWp, converted into one-minute irradiance and simulated with a 1 s average-value model; a 1 {μ}s switching model resolved the grid-current harmonics. Over the same months, the measured mean specific yield (4.13 kWh/kWp/day) agreed with the typical-year PVsyst estimate within 0.6 %, but monthly deviations ranged from {-}21 % to +27 %. Seasonal means were 3.49 (winter), 5.06 (pre-monsoon) and 3.72 kWh/kWp/day (monsoon). For an assumed demand of 11.2 e-bike sessions per valid day, PV supplied 73.7 %, the battery 22.9 % and the grid 3.3 % of the charging energy; winter and monsoon required 26--30 % battery support and accounted for nearly all grid import. Under deliberate model and sensor errors, the proposed recursive-least-squares (RLS) adaptive extended Kalman filter reduced the mean monthly state-of-charge RMSE to 0.58 %, versus 3.16 % for an extended Kalman filter. An RLS day-ahead PV forecast reduced the forecast RMSE by 10.5 % relative to persistence, yet lowered the operational energy cost by only 0.61 % under the assumed tariff. Under simulated grid-voltage distortion, a multi-resonant proportional-resonant controller achieved the lowest steady-state distortion, and RLS harmonic estimation reduced the current total harmonic distortion at 3 kW from 7.61 % to 1.74 %, with total demand distortion below 1.3 %; these are simulation-based comparisons, not an IEEE 519 compliance assessment.
No takes yet. Share an insight, caveat, or question.
SINGH et al. (2026) studied this question.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: