Answers are grounded in this paper and cite their sources.
Identifying a faulty cell from battery-management records is difficult when operating trends affect all cells and different diagnostic indicators favour different candidates. Here we present PhyFuseCell, a physics-anchored ranking method for packs with variable cell counts. Both branches reference cell voltages to the pack median: one characterizes charge-residual magnitudes and trends, while the other learns normalized discharge patterns. A shared cell encoder and scorer, together with valid-cell masking, accommodate different pack sizes. The evidence scores are standardized within each pack and combined with equal weights. On CH-BatteryGen packs with 28 or 124 cells, the compact implementation achieved the highest mean Top-1 localization accuracy among the evaluated methods, at 98.0 ± 2.7% across five vehicle-held-out splits, 7.0 percentage points above a validation-tuned clustering baseline. Paired predictions showed how complementary evidence corrected competing cell rankings. In self-discharge transfer without target-group training, adding target-pack charge evidence increased mean accuracy from 61.0 to 83.8% for 28-to-124-cell transfer and from 66.3 to 94.7% in reverse. These results support organizing physical and temporal evidence at the cell level to improve fault localization across the evaluated pack sizes.
No takes yet. Share an insight, caveat, or question.
Fei Fang (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: