High-frequency core loss constrains efficiency and power density, yet loss models do not identify which parts of an evolving domain-wall network carry the dominant reversal resistance. We present a physics-interpretable topological machine-learning workflow combining micromagnetic simulations, persistent homology, principal component analysis and inverse mapping for an idealized nanocrystalline soft-magnet model driven at nominal frequencies of 100 kHz–10 MHz using α = 1.0 and frequency-specific integration. Because reversal here is dominated by domain-wall motion, we treat the shape and energy of the wall network, captured by persistent homology, as the governing factor of loss. The first coordinate tracks magnetization, whereas the second captures frequency-associated domain subdivision and correlates with the exchange contribution to domain-wall energy. Their feature-space gradient reveals a reversal barrier near coercivity that increases with frequency. Inverse mapping localizes the largest contributions to propagating reversed-domain tips and selected fine wall segments rather than uniformly across the wall network. Consistent structure–energy–mechanism relationships connect the representation to magnetic physics. Within this protocol, reversal resistance is associated not simply with wall amount, but with a spatially selective subset of high-energy wall configurations. The workflow provides testable spatial descriptors for low-loss materials screening and optimization.