Answers are grounded in this paper and cite their sources.
Adhesive contacts can couple particle aggregation to wall capture at a pore throat, but flow decline alone does not reveal how an obstruction formed. We developed a force-resolved CFD–DEM workflow that separates particle–particle and particle–wall JKR contact adhesion in a matched 2 × 2 design across three random-seed blocks. The modified contact-history implementation was checked for post-contact separation, pair-force balance, and interaction-range limits. Hydraulic histories, particle accounting, signed contact forces, and a predeclared opposing-wall span criterion were evaluated at three coupled temporal settings. At the coarse T2 setting, combined adhesion gave C11/C00 final 50 ms resistance ratios of 2.217–3.042, with qualifying spans in two of three seeds. At T3 these ratios were 1.000–1.036, and at T4 they were 1.000–1.002; neither finer matrix produced a qualifying span. The same analysis workflow thus identifies a T2-specific simulated network and exposes its sensitivity to coupled temporal resolution. The results do not establish a converged physical prediction of adhesive bridging.
No takes yet. Share an insight, caveat, or question.
Musa et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: