Draft tube pressure pulsation (DTPP) is a major hydraulic excitation in Francis turbine units under low-load operation and can propagate to active power and speed oscillations through hydraulic-mechanical-electrical coupling. This study develops a DTPP-integrated MATLAB/Simulink model and a coordinated interval type-2 fuzzy PID/PSS controller termed Proposed IDBO-ACO. A nominal PSS solution is determined first; the subsequent joint search confines the PSS variables to its neighborhood while retaining the admissible governor-side ranges. Seed-matched optimizer tests and a paired anchoring comparison distinguish the effects of the improved optimizer and the anchored search. Across three representative operating-disturbance conditions, Proposed IDBO-ACO gives the lowest active-power, generator-speed total variation, overshoot, and settling time among the tested configurations. The statistical and dynamic-response evidence supports anchored coordination as the source of the additional improvement over unrestricted IDBO-based joint optimization within the tested simulations.