Answers are grounded in this paper and cite their sources.
Floating net cages (FNCs) in coastal aquaculture require a reliable, low-power electricity supply for daily operations. However, many coastal sites still have limited grid access and depend on fuel-based energy. This study compared the performance of a Savonius rotor and an H-type Darrieus rotor as renewable electricity options for FNC applications, using the same swept area of 0.45 m² and a shared direct-current generator interface under controlled laboratory airflow. A total of 560 operating points were recorded at wind speeds of 1.5–8.0 m/s under discrete resistive loads. Electrical power generation was derived from the measured voltage and current, while the wind-to-electric efficiency was determined as the proportion of generated electrical power to the available wind power. The findings indicated that the H-type Darrieus turbine exhibited superior performance compared to the Savonius turbine across the entire testing range. Its mean electrical power reached 7.59 W, compared with 4.47 W for the Savonius, while mean efficiency reached 17.01% and 10.09%, respectively. At 8.0 m/s, the H-type Darrieus produced 22.01 W, whereas the Savonius produced 12.47 W. These results indicate that the H-type Darrieus rotor is more suitable for the early-stage design of hybrid wind-solar-battery systems for FNC applications.
No takes yet. Share an insight, caveat, or question.
Herlina et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: