Key result
Three-variable nomogram predicts actionable arrhythmias on ICM with a C-index of ~0.71.
Why the study?
Prediction tools for actionable arrhythmias after implantable cardiac monitor implantation in patients with unexplained syncope remain limited.
Does a nomogram incorporating age, history of recurrent syncope, and first-degree atrioventricular block accurately predict actionable arrhythmias in patients with unexplained syncope undergoing implantable cardiac monitoring?
Cohort (n=302)
Yes
Does a nomogram incorporating age, history of recurrent syncope, and first-degree atrioventricular block accurately predict actionable arrhythmias in patients with unexplained syncope undergoing implantable cardiac monitoring?
A simple nomogram incorporating age, recurrent syncope, and first-degree AV block provides moderate discrimination for predicting actionable arrhythmias in patients with unexplained syncope receiving an implantable cardiac monitor.
Answers are grounded in this paper and cite their sources.
May inform ICM decisions in unexplained syncope; leaves open prospective validation before clinical adoption.
Prediction tools for actionable arrhythmias after implantable cardiac monitor (ICM) implantation in patients with unexplained syncope remain limited. This dual-center retrospective study included 302 patients divided chronologically into development (n = 91) and temporal validation (n = 211) cohorts. The endpoint was the first ICM-detected arrhythmia prompting permanent pacemaker or defibrillator implantation, catheter ablation, initiation of Vaughan Williams Class I or III antiarrhythmic drugs, or oral anticoagulation. A multivariable Cox model was developed and internally validated using 1000 bootstrap resamples, repeating variable selection and model fitting. During a median follow-up of 23.4 months, 78 patients reached the endpoint, including 32 in the development cohort and 46 in the temporal validation cohort. The nomogram included age, a history of recurrent syncope, and first-degree atrioventricular block. The optimism-corrected C-index was 0.720 in development. In temporal validation, the C-index was 0.707 (95% confidence interval, 0.623–0.790), and the 12- and 24-month time-dependent areas under the receiver operating characteristic curve were 0.733 and 0.741, respectively. The nomogram showed moderate discrimination in temporal validation at the same two centers. The model underestimated risk at 12 months, whereas mean predicted risk was closer to observed risk at 24 months.
No takes yet. Share an insight, caveat, or question.
Shen et al. (2026) conducted a cohort in Unexplained syncope with implantable cardiac monitor (ICM) implantation (n=302). Nomogram incorporating age, history of recurrent syncope, and first-degree atrioventricular block was evaluated on First ICM-detected arrhythmia prompting permanent pacemaker or defibrillator implantation, catheter ablation, initiation of Vaughan Williams Class I or III antiarrhythmic drugs, or oral anticoagulation (C-index 0.707, 95% CI 0.623-0.790). A nomogram using age, recurrent syncope, and first-degree AV block predicted actionable arrhythmias on ICM with a C-index of 0.707 in temporal validation.
Synapse has enriched 10 related papers. Consider them for comparative context: