Key result
Novel GATORS dual-guide technique enables successful PCI for non-engageable ostial RCA CTO.
Why the study?
This report presents a novel technique to manage ostial in-stent RCA CTO with an ambiguous cap and an antegrade guide that cannot be selectively engaged.
Case Report
Describes the novel GATORS technique using a two-guide rail over an externalized wire to achieve selective engagement and successful PCI in complex, non-engageable ostial in-stent RCA CTOs.
Answers are grounded in this paper and cite their sources.
May offer a bailout option in select non-engageable ostial in-stent RCA CTOs; hypothesis-generating and requires prospective validation.
We present a novel technique for effectively managing ostial In‐stent RCA CTO with an ambiguous cap and an antegrade guide that cannot be selectively engaged. We used a guide and a coronary wire to hook the ostial stent. We snared the wire with another guide catheter and externalized it, creating a rail of two guides over the wire that enabled selective guide engagement, provided excellent support, and resulted in successful PCI.
No takes yet. Share an insight, caveat, or question.
Raja et al. (2026) conducted a case report in Ostial in-stent right coronary artery (RCA) chronic total occlusion (CTO) with an ambiguous cap and non-engageable antegrade guide. GATORS (Guide Assisted sTent hOok and Retrograde Snare) technique was evaluated on Successful percutaneous coronary intervention (PCI) and selective guide engagement. The GATORS technique using two guides over an externalized wire enabled selective guide engagement and successful PCI in a non-engageable ostial in-stent RCA CTO.