Key result
Supra-annular AVR with Florida sleeve reinforcement prevents valve detachment at 2 years in Behçet's disease.
Why the study?
Patients with Behçet's disease undergoing aortic valve replacement for aortic regurgitation face significant risks of paravalvular leakage and prosthetic valve detachment.
Does supra-annular mechanical aortic valve replacement combined with Florida sleeve aortic root reinforcement prevent paravalvular leakage and prosthetic valve detachment in a patient with severe aortic regurgitation associated with Behçet's disease?
Case Report (n=1)
No
Does supra-annular mechanical aortic valve replacement combined with Florida sleeve aortic root reinforcement prevent paravalvular leakage and prosthetic valve detachment in a patient with severe aortic regurgitation associated with Behçet's disease?
Anchoring a supra-annular mechanical aortic valve to an external Florida sleeve Dacron graft rather than the inflamed native annulus offers a promising surgical approach to prevent prosthetic valve detachment and paravalvular leakage in Behçet's disease-associated aortic regurgitation.
Answers are grounded in this paper and cite their sources.
Hypothesis-generating for supra-annular AVR with Florida sleeve in Behçet's disease; prospective trials needed before clinical adoption.
Patients with Behçet's disease who undergo aortic valve replacement for aortic regurgitation face significant risks of paravalvular leakage and prosthetic valve detachment. We describe a novel surgical strategy that combines supra-annular mechanical prosthesis implantation with Florida sleeve aortic root reinforcement. By anchoring the prosthetic valve to an external Dacron graft rather than the inflamed native annulus, this strategy aims to reduce these risks in patients with Behçet's disease and aortic regurgitation.
No takes yet. Share an insight, caveat, or question.
Fu et al. (2026) conducted a case report in Severe aortic regurgitation and ascending aortic aneurysm associated with Behçet's disease (n=1). Modified supra-annular mechanical aortic valve replacement (23-mm Carbomedics Top Hat) with Florida sleeve aortic root reinforcement (30-mm Dacron graft) and ascending aorta replacement, plus postoperative corticosteroids and thalidomide was evaluated on Paravalvular leakage (PVL), prosthetic valve detachment (PVD), or coronary obstruction at 2 years. Supra-annular aortic valve replacement with Florida sleeve root reinforcement resulted in 0 cases of paravalvular leakage or valve detachment at 2 years in a patient with Behçet's disease.
Synapse has enriched 10 related papers. Consider them for comparative context: