Key result
Standardized BP measurement linked to ~46% higher 1-year hypertension diagnosis rates vs conventional assessment.
Why the study?
The effect of an office standardized blood pressure measurement model on community-based hypertension screening in Shanghai needed evaluation.
Does an office standardized blood pressure measurement (SBPM) model improve the detection rate of elevated blood pressure and 1-year diagnosis rate of hypertension compared with conventional blood pressure assessment in community screening?
Cohort (n=3,151,155)
Yes
Does an office standardized blood pressure measurement (SBPM) model improve the detection rate of elevated blood pressure and 1-year diagnosis rate of hypertension compared with conventional blood pressure assessment in community screening?
Implementing an office standardized blood pressure measurement model in community screening eliminates terminal digit preference and substantially improves the early detection and 1-year diagnosis rates of hypertension.
Answers are grounded in this paper and cite their sources.
May increase hypertension diagnoses in community screening; hypothesis-generating and requires RCTs before practice change.
Objective To evaluate the effect of an office standardized blood pressure measurement (SBPM) model on hypertension screening in the Shanghai community. Methods From January 1, 2019 to April 30, 2023, people aged 35-79 years old who underwent hypertension screening in the communities of Shanghai were selected. According to the blood pressure measurement method at the screening, the subjects were divided into the SBPM group and the conventional blood pressure assessment (CBPA) group, and the subjects were followed up for the diagnosis of hypertension within 1 year. The inverse probability of treatment weighting (IPTW) was used to balance confounding factors between the 2 groups. The differences in the distribution of the end digit of blood pressure values, the detection rate of elevated blood pressure, and the diagnosis rate of hypertension within 1 year after screening between the 2 groups were analyzed after IPTW analysis. Weighted logistic regression was used to evaluate the effect of hypertension screening using SBPM compared with CBPA. Results A total of 3,151,155 subjects were included in this study, including 110,487 subjects in the SBPM group and 3,040,668 subjects in the CBPA group. After IPTW analysis, the baseline characteristics were balanced between the 2 groups (standardized mean difference [SMD] < 0.1). The terminal digit frequencies of 0-9 for systolic and diastolic blood pressure values in the SBPM group ranged from 9.75% to 10.26% and 9.80% to 10.22%, respectively, with balanced distribution. However, those in the CBPA group ranged from 0.91% to 44.13% and from 1.27% to 42.71%, respectively, which showed an uneven distribution and an obvious preference for “0.” The detection rate of elevated blood pressure in the SBPM group (27.36%) was significantly higher than that in the CBPA group (2.85%, χ2 = 178,641.000, P < .001; after adjusting for confounding factors, OR = 13.40, 95% CI, 13.17-13.63). The association between blood pressure measurement methods and the detection rate of elevated blood pressure was more pronounced among men, subjects aged 35-44 years old, urban residents, those measured in winter, and during the medium-term promotion stage (P < .001 for interaction). Similarly, the diagnosis rate of hypertension within 1 year after screening in the SBPM group (13.20%) was significantly higher than that in the CBPA group (9.29%, χ2 = 1894.000, P < .001; after adjusting for confounding factors, OR = 1.46, 95% CI, 1.43-1.49). Stratified analysis revealed that the most pronounced increase was observed in subjects aged 35-44 years old (OR = 2.01, 95% CI, 1.87-2.16). Conclusions The quality of the data, the detection rate of elevated blood pressure, and the diagnosis rate of hypertension within 1 year using SBPM for hypertension screening are significantly superior to those with CBPA. This approach enhances early detection and diagnosis among the general population and should be promoted in community-based hypertension screening.
No takes yet. Share an insight, caveat, or question.
Wang et al. (2026) conducted a cohort in Hypertension screening (n=3,151,155). Office standardized blood pressure measurement (SBPM) model vs. Conventional blood pressure assessment (CBPA) was evaluated on Diagnosis rate of hypertension within 1 year after screening (OR 1.46, 95% CI 1.43-1.49, p=<0.001). Standardized blood pressure measurement increased 1-year hypertension diagnosis rates compared with conventional assessment.
Synapse has enriched 10 related papers. Consider them for comparative context: