Key result
Single-sensor PPG machine-learning model estimates ICU blood pressure with ~3.5 mm Hg MAP error.
Why the study?
Continuous blood pressure monitoring in the ICU primarily relies on invasive arterial catheterization, which carries risks of infection and thrombosis. An interpretable noninvasive blood pressure estimation framework using single-sensor photoplethysmography is needed to reduce reliance on invasive arterial lines.
Does an interpretable XGBoost machine learning framework using 30 physiologically informed single-sensor photoplethysmography features accurately estimate continuous systolic, mean, and diastolic blood pressure compared to invasive radial arterial catheterization in adult ICU patients?
Observational (n=100)
No
Does an interpretable XGBoost machine learning framework using 30 physiologically informed single-sensor photoplethysmography features accurately estimate continuous systolic, mean, and diastolic blood pressure compared to invasive radial arterial catheterization in adult ICU patients?
Answers are grounded in this paper and cite their sources.
An interpretable XGBoost machine learning model using 30 physiologically informed photoplethysmography features and one-point calibration provides accurate noninvasive estimation of MAP and DBP (meeting AAMI and BHS Grade A standards) in ICU patients.
Background Continuous, noninvasive blood pressure (BP) monitoring is clinically important for managing hemodynamic instability in the intensive care unit (ICU). However, current ICU practice primarily relies on invasive arterial catheterization. While this is the clinical gold standard for continuous measurement, it carries risks such as infection and thrombosis and is typically limited to select critical care settings. Objective To reduce reliance on invasive arterial lines, we developed an interpretable estimation framework for systolic blood pressure (SBP), mean arterial pressure (MAP), and diastolic blood pressure (DBP) from single-sensor photoplethysmography (PPG). Methods Synchronized PPG and arterial line 10-minute recordings from 100 patients in the ICU were analyzed. Using a hybrid feature selection strategy (RReliefF and intrinsic model–specific rankings), we reduced 201 initial features to an optimized subset of 30 core features. Model development and evaluation were designed to minimize information leakage and overfitting, incorporating nested cross-validation and patient-wise testing to assess generalizability across heterogeneous ICU populations. We developed and validated predictive models using machine learning techniques, specifically XGBoost (XGB), random forest, and support vector regression, with XGB serving as our primary model. Results Among the evaluated models, the Hybrid Top 30 XGB configuration provided the best balance between estimation performance, model compactness, and computational efficiency. The model achieved mean absolute errors of 8.61 mm Hg (SBP), 3.50 mm Hg (MAP), and 2.62 mm Hg (DBP). For MAP and DBP, mean difference (SD) values of −0.09 (4.54) mm Hg and −1.07 (3.51) mm Hg, respectively, satisfied the Association for the Advancement of Medical Instrumentation numerical criteria, while performance corresponded to Grade A according to the British Hypertension Society grading criteria. Although SBP exhibited greater variability, estimation performance was largely preserved using a physiologically informed subset of 30 features (approximately 15% of the original feature set). Feature importance analysis revealed distinct physiological feature patterns across SBP, MAP, and DBP estimation. Conclusions Interpretability analysis identified key predictors associated with wave reflection, systolic timing, low-frequency vasomotor activity, and autonomic regulation. By explicitly linking predictive features to underlying cardiovascular physiology, the proposed framework addresses a key limitation of existing black-box cuffless BP models. Ultimately, this study demonstrates that an optimized XGB framework using physiologically informed PPG features can provide accurate and computationally efficient BP estimation in ICU settings and may support the assessment of clinically relevant hemodynamic states using a single-sensor PPG platform. These findings provide a foundation for future development of more robust and generalizable interpretable BP estimation models and cuffless monitoring technologies.
No takes yet. Share an insight, caveat, or question.
LEE et al. (2026) conducted an observational in Hemodynamic instability / ICU care requiring arterial blood pressure monitoring (n=100). Hybrid Top 30 XGBoost single-sensor photoplethysmography (PPG) blood pressure estimation model vs. Invasive radial arterial catheter blood pressure monitoring (reference standard) was evaluated on Mean arterial pressure (MAP) estimation accuracy and agreement against invasive arterial line reference (MD -0.09 mm Hg (SD 4.54); MAE 3.50 mm Hg, 95% CI -8.99 to 8.80).
Synapse has enriched 10 related papers. Consider them for comparative context: