High-density mortar coatings are increasingly used to shield medical and industrial radiation facilities. Ten cement mortars were prepared at water-to-cement ratio 0.60, with fine aggregate partially replaced by barite powder, steel powder, or both at 10, 20 and 30 wt.%. Density, 28-day compressive strength and the linear attenuation coefficient were determined, the latter in narrow-beam geometry with a NaI(Tl) detector using 133Ba, 137Cs and 60Co at 0.356, 0.662, 1.173 and 1.332 MeV, and compared with WinXCom. All modified mortars were denser (2.06–2.29 versus 2.01 g/cm3) and stronger than the control. Best shielding came from 30% barite powder and from 20% barite powder with 10% steel powder, giving μ of 0.244 and 0.241 cm−1 at 0.356 MeV, statistically indistinguishable. The latter also gave the highest strength, 58% above the control, and reduced the half-value layer by 14.9% at 0.356 MeV. μ correlated strongly with density (R2 = 0.937–0.998), most weakly at 0.356 MeV where the high atomic number of barium enhances photoelectric absorption. WinXCom overestimated μ by 3.08 to 10.75%, the deviation reflecting entrapped air, not cross-section error. Combining both powders therefore matches the shielding of higher single-additive dosages at lower heavy-aggregate content while improving strength.