Answers are grounded in this paper and cite their sources.
Maintaining skeletal traction in patients with acetabular fracture dislocations and associated mechanical instability remains a challenge during computed tomography (CT) acquisition. Further, multiple transfers and prolonged periods without traction pose an increased risk for recurrent dislocation episodes following closed reduction while awaiting definitive surgery. In this technical report, a traction apparatus that includes a ratchet strap connected to a digital scale was applied to maintain skeletal traction during CT imaging of acetabular fractures with mechanical instability. A cohort of 15 patients (meanage=44.0 +/- 21.5 years old, 10M/5F, Table 1) was retrospectively reviewed following implementation of the described method with no dislocation episodes during serial CT imaging prior to operative fixation. This technique is low-cost, vendor-agnostic, and does not require additional radiation exposure to trainees or radiologic technologists to manually maintain traction.
No takes yet. Share an insight, caveat, or question.
Champagne et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: