Answers are grounded in this paper and cite their sources.
A stand-alone photovoltaic charger must switch from maximum power point tracking to constant-current, constant-voltage (CC–CV) charging whenever a LiFePO4 battery cannot absorb the available power. This simulation study derives design rules for this hand-over in low-cost digital chargers with a single 10–100 ms control loop. In the surplus-proportional hand-over (SPH), the charging law sets an allowable current, and the module voltage is raised above the maximum power point in surplus-proportional steps. Unlike constant power point tracking or model-based limiting, it needs no power reference or irradiance sensor. Convergence and noise analyses determine the step gain, filter, hysteresis and voltage-loop gain. SPH and eight noise-retuned baselines were compared in Simulink, Monte Carlo runs and 30 days of measured irradiance at two sites. All voltage-mode trackers harvested the same energy. At the nominal limit, SPH exceeded 1 A s of overcurrent charge in one of 800 Monte Carlo runs, or 19 without any exclusion window after load steps (other feedback controllers: 18–100%). Min-select on a filtered current reference had lower monthly totals but tracked 0.3–0.4 percentage points less efficiently. At 0.15 C, only CPG with a hold band had less overcurrent charge but stayed 7–8 times longer above the CV voltage.
No takes yet. Share an insight, caveat, or question.
Thành et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: