Answers are grounded in this paper and cite their sources.
Archives with a fixed replacement budget must choose which drives to replace. We compare a greedy risk-density policy with an age-based policy out of sample, treating budgeted replacement as a 0/1 knapsack problem. Backblaze drive statistics for two quarters of 2019 were used. The first quarter, with 115,231 distinct drives, estimated failure rates per model; 106,218 drives remained in the analysis population. The second quarter, sealed until the plan was frozen, gave the outcome. The budget was 5% of capacity. The greedy policy captured 2.18 failures per 1000 terabytes (TB), against 1.21 for the age policy: a difference of 0.97 failures per 1000 TB (95% interval 0.43 to 1.53), positive under the rule fixed in advance. Post hoc, without the half-terabyte or the six-terabyte class the difference is inconclusive. On first-quarter risks, the greedy value matched the exact optimum at four of five budgets and was within 0.003% at the fifth. On one operator's data, out-of-sample selection by estimated risk per terabyte captured more failures per terabyte than age-based replacement at the primary budget; post hoc, the advantage depends on the mix of drive classes and was not detected against ranking by model rate.
No takes yet. Share an insight, caveat, or question.
Luis Eduardo Muñoz Guerrero (2026) studied this question.