Answers are grounded in this paper and cite their sources.
The working performance of inclined helical anchors is crucial for implementing the national West-to-East Power Transmission strategy in the upper Yellow River basin and advancing the construction of power infrastructure in Northwest China. However, current design codes are primarily established for homogeneous soils and cannot be directly applied to interbedded strata composed of silt, fine sand, and silty clay. Furthermore, the bearing capacity and installation torque of inclined helical anchors in such layered strata are difficult to accurately predict. Therefore, based on a 750 kV transmission line project in Gansu, in situ uplift and compression loading tests were carried out on 11 small-inclination helical anchors with varied helix numbers, diameters and embedment depths. A coupled Eulerian–Lagrangian (CEL) large-deformation finite element model, a t-z load transfer method and a component-based installation torque model were then combined into an analysis framework of in situ back analysis, code formula recheck and cross-method verification to assess the applicability of current design methods to layered soils. The results show that ultimate capacities calculated directly from geotechnical investigation parameters reach only 20–45% of the measured values at a displacement equal to 10% of the helix diameter and are thus conservative. When equivalent internal friction angles back-analyzed from the measured curves (38° for the slightly dense state and 45° for medium-dense to dense states) are reintroduced into the code formulae, the mean ratio of calculated to measured capacity is 1.006, with a coefficient of variation of only 3.8%, and the two sets of values agree closely. Except for the shallowly embedded anchor T12, the t-z method agrees well with the measured curves within the small-deformation range (displacement below 10 mm) and applies to normally embedded anchors with a helix spacing ratio above 3 at service load levels. The component-based torque model, which incorporates the additional contribution of the soil column within one pitch, reproduces the growth of installation torque with depth and the torque steps at helix depths, but it generally underestimates the field values, mainly owing to the spatial variability of the strata and the real-time adjustment of the rotation rate; a safety margin should therefore be retained in design. The findings provide a reference for the design and installation of inclined helical anchors in layered soils.
No takes yet. Share an insight, caveat, or question.
FENG et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: