Answers are grounded in this paper and cite their sources.
Objective. Precise lung 4D-CT registration is extremely challenging due to large respiratory excursions. To capture such large-magnitude motion, existing deep learning methods typically adopt a unidirectional coarse-to-fine cascade strategy, which is vulnerable to error propagation because uncorrected coarse-level misalignments degrade subsequent finer-scale stages and often lead to spatially inconsistent deformations. While implicit neural representations (INRs) support continuous coordinate-based deformation modeling, traditional instance-specific INRs lack clinical efficiency and struggle to converge on global large deformations because of the absence of multi-scale semantic guidance. This study aims to bridge these gaps by developing a bidirectional multi-scale INR network that jointly handles large deformation modeling and localized structural fidelity. Approach. We propose a bidirectional multi-scale INR network. First, a generalized conditional INR framework is introduced to enable continuous deformation modeling without the need for retraining. Crucially, a bidirectional feature feedback mechanism built upon Swin Transformer injects high-level semantic priors into low-resolution streams, correcting coarse-level biases through top-down interaction. Furthermore, an anatomy-aware structural constraint is incorporated to promote anatomical consistency and local boundary alignment. Main results. Under the within-subject phase-held-out DIR-Lab protocol, the proposed method achieved a mean TRE of 1.28 mm and a folding rate of 0.0090%. A leave-one-case-out evaluation assessed subject-independent generalization, yielding a mean TRE of 1.53 mm and a folding rate of 0.0195%. On the independent POPI dataset, the method achieved a mean TRE of 1.84 mm and a folding rate of 0.0806%, demonstrating competitive cross-center performance. Inference took 0.33 s per case. Significance. The proposed framework effectively combines continuous coordinate modeling with deep learning efficiency, overcoming error propagation inherent in discrete coarse-to-fine strategies and preserving both global deformation consistency and local anatomical precision. Its sub-second inference and performance under leave-one-case-out and independent external testing support its potential for efficient image-guided radiation therapy workflows.
No takes yet. Share an insight, caveat, or question.
Liu et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: