Answers are grounded in this paper and cite their sources.
Grid-forming converters have become increasingly important in renewable-dominated power systems because of their capability to establish voltage and frequency references independently of the grid. Among various grid-forming approaches, virtual synchronous generator (VSG) control is widely utilized due to its ability to emulate the electromechanical behavior of synchronous machines. Nevertheless, severe current surges may arise when grid faults occur, posing considerable challenges to converter protection and operational reliability. To maintain current within permissible limits, virtual-impedance-based current-limiting schemes are frequently integrated into VSG-controlled converters. Although numerous studies have investigated current-limiting strategies and control enhancements, relatively little attention has been devoted to developing analytical models capable of accurately describing the fault-current evolution. In particular, the dynamic variations of the internal voltage source and frequency deviation are commonly simplified or neglected, which can lead to noticeable discrepancies between analytical predictions and actual transient responses. To address this issue, this paper develops a closed-form analytical framework for evaluating the short-circuit current behavior of a grid-connected VSG equipped with virtual-impedance current limiting during symmetrical three-phase faults. An analytical description of the internal voltage dynamics is first derived from the converter equivalent circuit together with the reactive power-voltage regulation mechanism. Subsequently, the interaction between the internal voltage and fault current introduced by the virtual impedance is incorporated into the model, enabling derivation of an explicit fault-current expression that accounts for both voltage and frequency transients throughout the fault process. The proposed formulation is validated through detailed MATLAB/Simulink studies under different operating conditions. Comparison results demonstrate that the developed approach provides accurate prediction of the dominant fault-current trajectories over the investigated operating conditions and offers useful theoretical support for protection assessment and transient analysis of converter-dominated power systems.
No takes yet. Share an insight, caveat, or question.
Zhu et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: