Answers are grounded in this paper and cite their sources.
Spray dust suppression in coal mines relies on the wetting of coal particles by the spray liquid. Most screening tests, however, assess only the first droplet–coal contact, although in practice coal dust undergoes repeated wetting, drying, and rewetting. A sedimentation-based protocol then treats initial wetting and the rewetting of dried, modified coal dust in deionized water as two independent dimensions. Twelve monomeric surfactants of four classes were screened at six concentrations (0.02–0.20 wt %), and the best were blended in equal volumes. Coal dust of two size fractions (d ≤ 0.150 and 0.075 mm) from the Chengzihe Coal Mine was tested, with the settling rate as a dynamic wetting proxy. Surfactant ranking differed between the stages and reversed with particle size, so a single contact measurement cannot predict field performance. A reproducible inflection at 0.04–0.06 wt % defined a practical concentration range. For coarse dust, monomers generally outperformed the blends (OP-10 and FPA-T strongest in initial wetting); for fine dust, the blends were superior, and FPA-T+AOS was the only system effective in both stages, making it the most suitable additive for the fine fraction. Contact angle, FTIR, and zeta potential explained this static–dynamic mismatch, providing a particle-size-dependent basis for additive selection.
No takes yet. Share an insight, caveat, or question.
Liu et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: