A tall building has to resist wind and earthquake forces in addition to the gravity loads, and as the height increases the lateral stiffness becomes the main design requirement. An outrigger system connects the lateral load resisting frame with the outer columns and helps in reducing the sway of the building without increasing the member sizes much. The location of the outrigger along the height has a direct effect on how well it works. This paper presents the seismic analysis of a G+30 reinforced concrete building, about 93 m high, with a plan of 36 m x 36 m. Six models are studied: a bare frame, outrigger at storey 10, outrigger at storey 20, and outriggers at storeys 5 and 15, 10 and 20, and 15 and 25. Response spectrum analysis is carried out in ETABS for Seismic Zone V. Storey displacement, base shear, time period, frequency, storey acceleration, storey drift, storey shear, torsion and bending moment are compared for all the models. The top displacement reduced by 8.2% to 21.6% and the top acceleration by 9.1% to 36.1% when outriggers were provided. The best performance was seen for the outriggers at storeys 15 and 25.