Particle size is a central formulation variable for polymeric nanocarriers intended for delivery applications. In this study, polylactide (PLA) and poly(lactide- co -glycolide) nanoparticles were prepared by nanoprecipitation, and the particle size was examined as a function of polymer molecular weight, organic solvent, polymer concentration, organic-phase fraction, and stabilizer. In water-miscible solvents, the PLA particle diameter generally increased with molecular weight, but the magnitude of the increase depended on the solvent. Acetonitrile produced 79 ± 10 nm particles from 111 kDa PLA, whereas 1,4-dioxane restrained the size increase from 170 kDa upwards. Reducing the concentration of 170 kDa PLA in acetonitrile from 1 to 0.0625 wt % decreased the hydrodynamic diameter from 120 ± 8 to 58 ± 4 nm. At a fixed PLA molecular weight (170 kDa), the measured diameter depended strongly on the stabilizer and ranged from 79 ± 12 nm with Tween 80 to 180 ± 20 nm with sodium dodecyl sulfate. By contrast, ethyl acetate produced micrometer-scale PLA particles spanning approximately 1–10 µm. The dispersions characterized in detail were narrowly distributed (PDI 0.08–0.16) and negatively charged (zeta potential from −12 to −16 mV); scanning electron microscopy confirmed a regular spherical morphology. These results define the conditions under which high-molecular-weight PLA can be brought into the sub-100 nm range targeted for carriers in neutron capture therapy.