Answers are grounded in this paper and cite their sources.
Study Design: Systematic review and meta-analysis. Objective: To estimate the reported incidence of instrumentation failure following instrumented surgery for metastatic spine disease and explore study-level differences by cement augmentation and surgical approach. Background: Instrumentation failure may result in recurrent mechanical pain, deformity, neurological compromise, or revision surgery. However, its reported incidence varies because of inconsistent outcome definitions, surveillance methods, and follow-up duration. Methods: PubMed/MEDLINE and Embase were searched from database inception through May 2026. Eligible studies enrolled patients with metastatic spine disease who underwent instrumented surgery and reported instrumentation failure with an extractable at-risk denominator and were retained in the systematic review. Quantitative pooling further required isolatable, mutually exclusive instrumentation failure counts in metastatic instrumented cohorts; 1 composite-endpoint study was included in sensitivity analysis, and 1 mixed metastatic–primary cohort study was excluded from pooling but retained for descriptive review. Logit-transformed proportions were pooled using DerSimonian–Laird random-effects models with a 0.5 continuity correction applied to event and nonevent counts for all studies. Exploratory subgroup analyses were performed by cement augmentation and surgical approach. Results: Forty-two studies underwent data extraction. The primary meta-analysis included 40 studies comprising 2209 instrumented patients and 56 instrumentation failure events. The pooled reported incidence was 4.07% (95% CI, 3.26%–5.08%; I 2 = 0%). Sensitivity analysis including the composite-endpoint study comprised 41 studies, 2371 patients, and 107 events, yielding a pooled incidence of 3.80% (95% CI, 2.43%–5.89%) with substantial heterogeneity (I 2 = 75.4%; P < 0.01). Pooled incidence did not differ significantly by cement augmentation ( P = 0.23) or surgical approach ( P = 0.34). Conclusion: Instrumentation failure following instrumented surgery for metastatic spine disease appears uncommon, with a pooled reported incidence of ∼4%. Inclusion of a composite endpoint introduced substantial heterogeneity, underscoring the need for standardized instrumentation failure definitions. Findings regarding cement augmentation and surgical approach were exploratory and should not be interpreted causally. Level of Evidence: Level III.
No takes yet. Share an insight, caveat, or question.
Vargas et al. (2026) studied this question.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: