Answers are grounded in this paper and cite their sources.
Purpose To develop a reproducible technique for coating high‐strength sutures with doxycycline or vancomycin and to compare the antibiotic elution profiles of round and tape‐style sutures over time in an in vitro model. Methods In this in vitro study, 2 round (No. 2 FiberWire [PE‐R, polyethylene‐core round], No. 2 ActivBraid [COL‐R, collagen‐integrated round]) and 2 tape‐style (1.5 mm LabralTape [PE‐T, polyethylene‐core tape], 1.5 mm ActivBraid [COL‐T, collagen‐integrated tape]) sutures were dip‐coated in gelatin solutions containing low (C1) or high (C2) doxycycline or vancomycin concentrations. After drying, 1‐cm segments were incubated at 37°C, and daily aliquots were collected over 7 days. Antibiotic release was quantified by enzyme‐linked immunosorbent assay. Results Total doxycycline and vancomycin elution ranged from 83.6 to 151.8 ng and 261.3 to 319.1 ng, respectively. Doxycycline showed first‐order‐like elution, with the greatest occurring during days 1 to 3. In contrast, vancomycin showed near‐constant elution with minor fluctuations over time. At individual timepoints, COL‐T (C1D) released more doxycycline than COL‐R on days 2 and 3, whereas COL‐T released more than COL‐R on day 5 in C2D. COL‐R (C1V, C2V) released more vancomycin than PE‐R on day 5. Conversely, COL‐R (C2D) released less doxycycline than PE‐R on day 6. Intergroup comparisons showed that PE‐T released more vancomycin in C2V versus C1V on day 3, and PE‐R released more vancomycin in C1V versus C2V on day 5 and more doxycycline in C1D versus C2D on day 6. Conclusions Coating commercial high‐strength sutures with either doxycycline or vancomycin using a gelatin‐based dip‐coat produced measurable, but low‐level, antibiotic elution over 7 days in this in vitro model. Doxycycline exhibited a release profile consistent with first‐order kinetics characterized by a higher initial burst followed by tapering elution, whereas vancomycin showed a more sustained release pattern consistent with near zero‐order kinetics. Among the coated constructs, COL‐T sutures exhibited the greatest doxycycline elution, whereas COL‐R sutures exhibited the greatest vancomycin elution relative to PE‐R sutures. Clinical Relevance Antimicrobial coating of high‐strength orthopaedic sutures enables sustained local antibiotic elution and may provide a potential strategy for reducing the early postoperative infection risk in tendon and ligament repairs.
No takes yet. Share an insight, caveat, or question.
Maity et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: