Answers are grounded in this paper and cite their sources.
Introduction Transvaginal ultrasonographic cervical length measurement is used to assess the risk of spontaneous preterm birth (sPTB), but its predictive performance varies across populations and measurement thresholds. This meta-analysis aimed to systematically evaluate its diagnostic efficacy for predicting sPTB. Methods PubMed, Embase, Cochrane Library, Web of Science, CNKI, WanFang Data, and VIP were searched from inception to May 31, 2025. Diagnostic studies evaluating transvaginal ultrasound cervical parameters for predicting sPTB were included. Pooled sensitivity, specificity, likelihood ratios, diagnostic odds ratio (DOR), and summary receiver operating characteristic (SROC) curve were calculated using random-effects models. Results Twelve studies involving 24,363 pregnant women were included. For cervical length ≤25 mm predicting sPTB <34 weeks, pooled sensitivity was 0.708 (95%CI: 0.645–0.765), specificity 0.898 (95%CI: 0.893–0.903), and DOR 14.524 (95%CI: 7.988–26.410), with an SROC area under the curve of 0.840. The predictive efficacy increased with stricter sPTB definitions (<37 weeks: DOR=6.34; <34 weeks: DOR=14.52; <33 weeks: DOR=27.71). Combined cervical length and funneling assessment yielded higher diagnostic performance (DOR=15.60) than either parameter alone. Subgroup analyses showed that a cutoff of ≤25 mm provided optimal diagnostic performance. Begg's test ( P = 0.193) indicated no significant publication bias. Conclusion Cervical length measurement may contribute to sPTB risk assessment, but the certainty of evidence was low for sensitivity and very low for the other main accuracy estimates. The findings should be interpreted cautiously and do not establish the benefit of routine screening.
No takes yet. Share an insight, caveat, or question.
Ma et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: