Introduction: The performance of Fe 3 O 4 nanofluid in concentric pipe heat exchangers was evaluated against pure water and ethylene glycol as baselines to determine thermal–hydraulic feasibility. Materials and methods: This was achieved by computationally modelling heat transfer across straight, 90° T-shaped and 45° Y-shaped double-pipe geometries and two single-bend controls (a 90° elbow and a 45° bend), with water or ethylene glycol in the inner tube. Results: The nanofluid raised the annulus-side convective heat transfer coefficient by a factor of 1.114–1.126 in every geometry and leg ( h ∝ k 0.53 for a 23% rise in conductivity), with no change in friction factor or pressure drop. Because the annular film carries 38–52% of the thermal resistance with water in the inner tube and about 7% with ethylene glycol, the overall coefficient rose by 4.2–6.0% and 0.7–1.4%, respectively. Junctions and bends raised the local wall heat flux by 10–31% within about 0.2 m of the junction but contributed at most 2% of the heat duty; downstream legs recovered the straight-pipe coefficient within 1.3%, and the junctions added loss coefficients of 0.2–1.4. Conclusions: An ultra-dilute Fe 3 O 4 suspension gives a modest, penalty-free gain that scales with the share of thermal resistance on the side where it is used, whereas junctions and bends act only locally and at a pressure cost; the two effects are independent and additive.