Adding photovoltaic (PV) capacity to an operating wind farm can increase delivered energy without increasing investment value. We assess a conditional PV retrofit at Kalfaköy, Türkiye, using hourly wind-generation records and market prices for 2021–2023, modelling same-site PV production with a 2025 mean-price reference. The wind-only counterfactual retains the same export limit. With a 10 MW limit, adding 10 MWp PV supplies 9.62–9.75 GWh/year but produces a 20-year incremental net present value (NPV) of −7.22 to −7.17 million USD at 66.42 USD/MWh and 1095 USD/kW direct current (DC). Price-shape, connection-availability and fixed-cost assumptions change marginal decisions at 140 USD/MWh. An analytical screening sequence distinguishes insufficient unconstrained PV value from connection losses and tests whether any positive capacity is worth evaluating. A controlled 2024 comparison uses four additional Turkish wind-only operating profiles and the existing hybrid Kangal baseline with common economic assumptions. All 180 fixed 10 MWp sensitivity treatments are negative at the reference price; some become positive at 140 USD/MWh, depending on site and assumptions. Accounting for existing PV at Kangal changes the additional-capacity decision. The results support transparent conditional screening, not universal investment thresholds or verified project returns.