Answers are grounded in this paper and cite their sources.
We simultaneously performed in situ two-dimensional thermography and digital imaging of cm2-scale coating films (4 cm × 4 cm to 4 cm × 8 cm), thereby mapping the surface temperature and brightness during drying. We defined the onset of the local decreasing-rate drying period via two-dimensional thermography and defined the moment at which local surface brightness stabilized via digital imaging, which was ascribed to the complete surface solidification of the coating. Quantitative analysis revealed a strong correlation between these two measures, with over 85% of the data points falling within a 25% error margin. These results demonstrate that the optically determined time point can serve as a practical indicator of the transition to the decreasing-rate drying period, enabling two-dimensional mapping of drying heterogeneity across coating films. While mapping drying uniformity is inherently challenging, simple digital imaging represents a scalable, cost-effective solution for visualizing localized drying kinetics and preventing defect formation.
No takes yet. Share an insight, caveat, or question.
Hira et al. (2026) studied this question.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: