Answers are grounded in this paper and cite their sources.
Emissions from electricity generation depend on which plants supply demand as well as on the installed plant stock. This paper develops a repeatable ex-post appraisal that compares realised monthly generation with an emissions-ordered benchmark in three steps: an idealised reallocation, bounds that add ramping and minimum-generation constraints, and a validity layer that treats plants with duplicated capacity factors at the level at which their activity is identified and caps utilisation at observed levels. The procedure is applied to plant-month data for thermal and biomass plants in Vietnam, Thailand, and Indonesia from 2021 to 2024. The idealised benchmark implies a gap of roughly one quarter of emissions, and operational constraints alone reduce it to between 8% and 18%. Once data validity and utilisation ceilings are imposed, the preferred estimate is about 2%, with a combined range of 1.3–3.4% across specifications, and it is concentrated in a few grid zones. Ownership associations are exploratory and do not survive the validity restriction. The framework is proposed as a screening tool for periodic environmental assessment, with reporting rules that separate benchmark values, bounds, and data quality, rather than as a dispatch optimiser.
No takes yet. Share an insight, caveat, or question.
Quoc Lap Nguyen (2026) studied this question.