In this study, we investigated the use of a Li-selective membrane synthesized with the incorporation of hydrogen manganese oxide (HMO) to simplify the extraction process. The HMO-loaded membranes (HMOM) displayed remarkable performance for direct lithium extraction (DLE). The major accomplishments of incorporating HMO within the polymeric substrate were 2-fold. First, fast kinetics were observed for HMOM; ∼90% capacity (15 mg/g) was attained in 5 min in the filtration mode, with a pseudo-second-order kinetic rate constant (k2) ∼20 times higher as compared to the batch test, owing to enhanced mass transfer within the regulated channels of the membrane. Second, incorporation of HMO in the poly(ether sulfone) matrix reduced the Mn loss by five times and showed only <0.2% Mn loss per cycle during the DLE from produced water (PW) matrix. We showed that the acid concentration can be reduced by 10 times for Li recovery, which further displayed an additional 4-fold decrease in Mn loss but led to a ∼10% decline in Li recovery performance. HMOM also demonstrated competitive selectivity for Li against competing cations within PW, with a separation factor of ∼20–40. We demonstrate a multipass, multistage filtration process as a framework for sequential DLE, concentration, and purification from real PW.