Answers are grounded in this paper and cite their sources.
A generalized homogenized plate model is assessed for the forced vibration of equal-mass body-centered cubic (BCC), face-centered cubic (FCC), and Octet lattice-filled cantilever plates. The five-degree-of-freedom model combines an energy-based generalized stiffness of the periodic lattice supercell with lattice-resolved inertia and is compared with detailed three-dimensional Timoshenko beam-lattice models. Natural frequencies, mode shapes, acceleration frequency-response functions, and band-root-mean-square (RMS) response are examined over 0.5–300 Hz. For the investigated panel, first-frequency differences are below 3.3%, and selected peak-magnitude and band-RMS differences remain below approximately 3.1%. These scalar measures do not imply equally small differences at individual frequencies near resonance. At a common mass of 0.2 kg, BCC has a lower first transverse frequency and a band-RMS response about 1.8–1.9 times that of FCC and Octet. The topology ranking persists over assumed damping ratios of 0.5–5%. Radius scaling identifies a predominantly bending-controlled response for BCC and stretching-controlled responses for FCC and Octet. Localization screening places the first candidates above the operating band. The results establish a focused numerical assessment of transverse bending response for the studied cantilever configuration.
No takes yet. Share an insight, caveat, or question.
Mehralian et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: