Background Aorto-esophageal fistula (AEF) is a rare but potentially fatal complication of button battery ingestion in children. While traditionally considered an acute event, increasing evidence suggests a delayed onset, even after battery removal. However, the temporal pattern of AEF development has never been systematically characterized, and the duration of risk after ingestion remains unclear. Methods A structured literature review was performed following PRISMA principles, focusing on pediatric cases of AEF secondary to button battery ingestion. The primary outcome was the time between button battery removal and AEF onset. Secondary variables included demographic data, timing of battery removal, anatomical localization, and clinical outcomes. Results Fourteen pediatric cases were included. Among patients for whom the timing of battery removal was available, the median time from ingestion to battery removal was 14 h (IQR 5–16 h; range 4–24 h). Among patients in whom AEF developed after battery removal and the post-removal interval was available, AEF developed a median of 18 days after removal (IQR 9–21 days; range 9–35 days). The overall mortality rate was 43% (6/14). Conclusions AEF after button battery ingestion is predominantly a delayed complication and early battery removal does not eliminate risk. Need for prolonged vigilance and prompt evaluation of delayed warning signs is warranted.