The goal of this study is to utilize wood‐based materials in the development of fire‐resistant drywall systems suitable for use as partition walls in timber buildings and as safe passages in the event of occurrence of fire. Five designs were developed and presented in this study, from which the most appropriate design can be selected based on specific building requirements and cost considerations, without the need for the initial treatment of the wood‐based materials with flame‐retardant chemicals. Results from this study demonstrated that untreated plywood can be used to develop fire‐resistant drywalls, with performance depending on wall design and plywood thickness. Several designs met the F60 requirement and are suitable for fire‐protected applications in timber buildings.