A dual-sorbent system consisting of a granular activated carbon (GAC) pretreatment followed by polishing with styrene-functionalized β-cyclodextrin (StyDex) beads was evaluated for removal of four per- and polyfluoroalkyl substances (PFAS: PFOA, PFHxA, PFBA and PFHxS) and two pharmaceuticals, bezafibrate (BEZ) and diclofenac (DCF), from municipal wastewater. Building on previous pilot evaluations of StyDex as a stand-alone sorbent, this study evaluates its integration into a treatment train with GAC pretreatment, examining GAC replacement frequency and selection of polishing sorbent to more effectively remove mixtures of PFAS and other trace organic contaminants from municipal wastewater. Upstream GAC pretreatment was used to nonselectively remove target compounds, dissolved organic carbon (DOC), and other competing background wastewater constituents to enhance downstream polishing performance. System performance was evaluated by comparing individual removal of target compounds by GAC-StyDex and GAC-ion-exchange resin (IXR) treatment trains and assessing the impact of periodic GAC replacement on polishing performance. Combining GAC pretreatment with StyDex polishing demonstrated the highest total removal of PFOA, PFHxS, and DCF over the duration of the pilot, and improved removal of the weaker sorbing compounds, PFHxA, BEZ, and PFBA. However, PFBA was not effectively controlled over the full pilot duration and exhibited substantially lower cumulative removal (55%–62%) in the GAC-StyDex and GAC-IXR trains, compared to the other five target compounds, which all had >93% removal. Extending the GAC replacement interval from 2,500 to 5,000 BV increased sorption capacity by 59.9% (0.177 to 0.283 μmol g–1), allowing greater GAC bed utilization prior to replacement while also maintaining low effluent concentrations after polishing. Compared with GAC-IXR, GAC-StyDex had 87.4% greater sorption capacity (0.283 vs 0.151 μmol g–1) on a mass-normalized basis and similar performance on a sorbent-volume basis, demonstrating StyDex as a high-capacity alternative sorbent for downstream polishing. These findings demonstrate the potential for integrating GAC pretreatment with downstream polishing to improve contaminant removal, maintain low effluent concentrations, enhance sorbent utilization, and inform the design of scalable wastewater treatment systems.
No takes yet. Share an insight, caveat, or question.
Shapiro et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: