Answers are grounded in this paper and cite their sources.
Background To evaluate the utility of transabdominal ultrasound in children with colorectal pathology (anorectal malformation, functional constipation and Hirschsprung’s disease) to assess the outcome of bowel management. Collect data to calculate age-dependent cut-offs of the transrectal diameter (TRD) in children with faecal load. Methods Prospective cohort study with subgrouping for a-/symptomatic patients and a healthy control group. Derived control group for adjusting sex-ratio in patients with Hirschsprung’s disease (4:1 ratio for male to female). 380 patients during a 31-month period were included. The transrectal diameter was measured routinely during the bowel management program after 1/3/6 months. Treatment options were oral laxatives, transanal irrigation or combination of both. For calculation of an age-dependent TRD cut-off, receiver operating characteristic, linear regression and locally estimated scatterplot smoothing were determined. The cut-off value was chosen based on a positive likelihood ratio > 10. Diagnostic accuracy was evaluated by the area under the curve, sensitivity and specificity. Results In the symptomatic subgroups of all cohorts the median values of TRD were significantly elevated compared to asymptomatic subgroups or control groups (p < 0.001). Successful bowel management had a large to very large effect on the TRD (Cohen’s d = 1.05 – 1.81) and mean values were significantly lower (p = 0.015 – 0.001). TRD and age showed a minor association with a non-linear positive trend without significant influence after age stratification. Receiver operating characteristics determined a collective cut-off for all cohorts of 2.985 cm in children ≥ 1 year old (positive likelihood ratio = 36.09; sensitivity = 81.92 %; specificity = 97.73 %; area under the curve = 0.91 (95%-CI 0.87 – 0.94); accuracy = 88.67 %). Conclusions Measuring the TRD is a radiation-free alternative method to assess faecal loading and monitoring response to bowel management in patients with colorectal pathology. TRD was consistently increased in symptomatic patients and decreased following successful treatment. Diagnostic thresholds were close to 3 cm across all cohorts, with good diagnostic performance. This study extends patient cohorts for transabdominal ultrasound and supports further multicentre validation of a standardized ultrasound protocol. Clinical trial number Not applicable.
No takes yet. Share an insight, caveat, or question.
Erkel et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: