Answers are grounded in this paper and cite their sources.
Background: Running cadence should be assessed with systems that demonstrate acceptable agreement with a reference method and adequate repeatability under the intended testing conditions. Aim: To quantify criterion agreement with high-speed video and 48-hour test–retest repeatability of a microcontroller-based contact-mat cadence counter during controlled in-place running. Methods: Thirty track and field athletes completed a 60-s in-place running trial on a microcontroller-based contact mat while synchronized 240-frames/s video was recorded. Independently reviewed and adjudicated video counts served as the criterion; contact-mat testing was repeated after 48 h. Agreement was assessed using ICC(A,1), absolute-error indices, and Bland–Altman statistics. Repeatability was quantified using ICC(A,1), SEM, MDC95, and session limits of agreement. Results: Criterion ICC(A,1) was 0.995 (bootstrap 95% CI 0.990–0.997); MAE was 1.10 spm, RMSE was 1.40 spm, and MAPE was 0.63%. Mean device–video bias was −0.10 spm, with 95% limits of agreement from −2.89 to +2.69 spm. Test–retest ICC(A,1) was 0.990 (bootstrap 95% CI 0.979–0.995), with SEM of 1.44 spm and MDC95 of 3.98 spm. Conclusions: The contact-mat counter yielded closely aligned aggregate cadence values and favorable short-interval repeatability in a fixed 60-s in-place task. These estimates are protocol-specific and do not establish interchangeability with overground running systems or performance in competition settings.
No takes yet. Share an insight, caveat, or question.
Akhmad et al. (2026) studied this question.