Answers are grounded in this paper and cite their sources.
Background: Most published robotic enhanced-view totally extraperitoneal (eTEP) hernia repair series report follow-up under 12 months and recurrence rates of 1% to 3%. Methods: We retrospectively analyzed 65 consecutive patients undergoing robotic eTEP incisional hernia repair at a single center (2019 to 2025; Da Vinci Xi system); recurrence-free survival was estimated by the Kaplan-Meier method. Results: Median follow-up was 27.9 months (range: 11.7-76.2). The overall recurrence rate was 4/65 (6.2%); all 4 recurrences occurred in patients with follow-up ≥24 months (4/41, 9.8%), with none before 24 months. Kaplan-Meier recurrence-free survival was 97.1% (95% CI: 91.8-100%) at 36 and 48 months. Primary fascial closure was achieved in 100% of cases, and the short-term complication rate was 9.2% (Clavien-Dindo grade I-II only). Conclusions: Because all recurrences emerged beyond 24 months, follow-up periods shorter than 24 months may fail to detect late clinical recurrences after eTEP repair.
No takes yet. Share an insight, caveat, or question.
Canal et al. (2026) studied this question.